0 Items

Symmetric high-frequency cables / switchboard cables

Symmetric high-frequency cables / switchboard cables

Cables for telephone switches and switchboard back panels. For the transmission of high-frequency signals in telecommunications equipment such as telephone switches and switchboard back panels, LEONI provides symmetric high-frequency cables and switchboard cables for transmission frequencies up to 32 MHz. These possess outstanding mechanical properties and are applicable for fix and mobile use. With a flame retardant and non corrosive cable jacket (FRNC), they are suitable for use with both indoor and outdoor applications. Due to small outer diameters and their high flexibility, high-frequency and switchboard cables from LEONI can be installed with low bending radii.

LEONI cables feature excellent electromagnetic shielding and a uniform foaming of the dielectric. One of LEONI’s specialities is skin-foam-skin extrusion (LEONIzell®).

  • Temperature range from – 20 °C up to + 70 °C
  • VDE, UL and CSA approval
  • Highly flexible
  • High voltage stability
  • Flame retardant and halogen free
Order number L45467-F4814-C6 L45467-Y515-C26 V45482-D87-G6
AWG 26 25 24
Type designation 02YS(ST)CH 48X2X0.4/0.8-120 BD GR FRNC S-09YS(ST)CH 32X2X0.5 STVIII BD GE S-09YS(ST)CH 8X2X0.6/1.2 BD GR FRNC
Jacket material FRNC FRNC FRNC
Mechanical properties
Outer diameter 13.5 mm (0.531 in) 13.4 mm (0.528 in) 9.1 mm (0.358 in)
Weight 256 kg/km (172 lb/1000 ft) 238 kg/km (160 lb/1000 ft) 117 kg/km (79 lb/1000 ft)
Permissable temperature range –33 °C up to 80 °C (–27 °F up to 176 °F) – 25 °C up to 70 °C (–13 °F up to +158 °F) – 40 °C up to 70 °C (–40 °F up to +158 °F)
Electrical properties
Impedance (120 ± 15) Ohm (135 ± 20) Ohm (120 ± 12) Ohm
Capacity 40 nF/km 42 nF/km
NEXT 1 MHz 50 dB 85 dB 50 dB
Attenuation values 24 dB/100 m (at 100 MHz) 105 dB/km (at 32 MHz)
Characteristics and standards
  • jacket material acc. to DIN EN 50290-2-27 (HD 624.7)
  • flame retardant acc. to IEC 60332-1-2
  • jacket material acc. to DIN EN 50290-2-27 (HD 624.7)
  • flame retardant acc. to IEC 60332-1-2
  • similar to TS 0031/96 part 3
  • RoHS compliant
  • jacket material acc. to DIN EN 50290-2-27 (HD 624.7)